PARA-HPAC-3400AR-G
  • C-Band 5.85 - 6.425 GHz
  • Power Output 400W Psat 56 dBm
  • RF Output Sample Port
  • 20 dB RF Gain Adjustment

Teledyne Paradise Datacom 400W C-Band 3RU Rack Height GaN SSPA

Paradise HPAC3400A Features

  • C-Band 5.85 - 6.425 GHz
  • Power Output 400W Psat 56 dBm
  • RF Output Sample Port
  • 20 dB RF Gain Adjustment

Teledyne Paradise Datacom has a rich history in the design and production of Gallium Nitride (GaN) based SSPAs. Our engineers utilize innovative linearization techniques that enable GaN amplifiers to produce linear output power with the same efficiency as tube based amplifier systems. A complete family of Satcom amplifiers has been developed that cover S-Band through Ku-Band.

GaN amplifiers have a superior set of mutually beneficial characteristics, including:

  • Higher Output Power
  • Greater Power-Added Efficiency
  • High Reliability

These GaN amplifier modules are installed in the popular 3RU (5.25 inch high) Chassis, which features a front panel display and five fault condition LEDs that reflect some of the SSPA major fault states. Local/Remote and Mute/Unmute LEDs show the current control mode and mute state of the amplifier.

A full compliment of remote monitor and control of the amplifier is available at the rear panel, including: RS-232/RS-485; Ethernet, with UDP and SNMP control; Web Browser TCP/IP; and Discrete hardware (parallel port) signals.

Features

  • Extremely High Power Density:
        to 600 W S-Band
        to 800 W X-Band
        to 800 W C-Band
        to 500 W Ku-Band
  • Removable Fan Tray and M&C Card Assembly
  • Remote Communication via RS232/485 or Ethernet
  • RF Output Sample Port
  • 20 dB RF Gain Adjustment
  • True RF Output Power Measurement
  • Built-in Maintenance Switch Controller

Options

  • Remote Control Panel
  • L-Band Input operation
  • Reflected Power Monitor
  • Input Sample Port
  • 1RU N+1 Power Supply
  • Exhaust Duct Adapters
  • Redundant Systems
  • Phase Combined Systems

 
 
 

1RU N+1 Redundant Power Supply

The combination of a separate, fully redundant power supply is an excellent means of obtaining the ultimate in system reliability. The power supply is an N+1 redundant configuration, meaning that there is one more power supply module available than required to operate the SSPA. A failure of one power supply module will not take the amplifier off the air.

L-Band Operation

Teledyne Paradise Datacom amplifiers are available with an integrated L-Band Block Up Converter. L-Band units utilize Teledyne Paradise Datacom’s proprietary zBUC technology. The addition of a zBUC® converter to the SSPA typically increases the gain by 2-4 dB. The advantages of zBUC technology include:

  • zBUC converter can detect and switch to an extenally supplied reference.
  • Optional internal high stability (10MHz) reference.
  • zBUC converter can lock to an externally supplied reference of 10 or 50 MHz.
  • zBUC converter can accept a wide range of external reference power (-10 to +5 dBm).

Redundant and Phase Combined Systems

Teledyne Paradise Datacom’s 3RU Rack Mount SSPAs can be configured in a variety of redundant and phase combined configurations.

  • 1:1 Redundant System with Internal Redundancy Control
  • 1:1 Redundant System with RCP2-1100 Redundant System Controller
  • 1:1 Fixed Phase Combined System with FPRC-1100 Phase Combined System Controller
  • 1:2 Redundant System with Internal Redundancy Control
  • 1:2 Redundant System with RCP2-1200 Redundant System Controller
  • 1:2 Fixed Phase Combined System with FPRC-1200 Phase Combined System Controller

System Output Power Capacity

Due to residual losses inherent in redundant system configurations (waveguide bends; switch and coupler losses), reduce the typical output power specification of a single amplifier by approximately 0.2 dB for 1:1 and by 0.4 dB for 1:2 systems.

In phase combined systems, these same losses result in slightly less than the ideal addition of 3 dB to the output power of a single HPA unit. For 1:1 phase combined systems, the typical additive output power is approximately 2.70 dB above the output power of a single HPA. For 1:2 phase combined systems, the typical additive output power is approximately 2.50 dB above the output power of a single HPA.

Actual system losses will vary based on the system options.

System Controllers

The RCP2/FPRC-1100/1200 system controller provides an extremely user friendly interface for complete monitor and control of the amplifier system.

RCP2-1100 Redundant System Controller

The front panel mimic display shows the on-line amplifiers and the switch positions. Fault lights are provided for easy identification of system status. All system monitor and control is available locally at the front panel LCD display, as well as remotely by the RS232, RS485, or Ethernet interface ports. Audible alarms and a full compliment of parallel I/O signal are available at the rear panel of the controller.

More Information
Weight75.0000
Country of Manufacture
ManufacturerTeledyne Paradise Datacom
Prime FrequencyC-Band
Amplifier TypeGaN SSPA
Rated Output Power400W
Power Rating MethodPSAT
Output Frequency5.850 - 6.425 GHz
Input Power180 - 265 VAC
Power ConsumptionPsat 1800W / Plin 1600W
Dimensions3RU