• Home
  • Terrasat Ku-Band Intelligent Block Upconverter (IBUC) 4 - 50W




Terrasat Ku-Band Intelligent Block Upconverter (IBUC) 4 - 50W

(0) No Reviews yet
  • Lower terminal cost
  • Simplified 1+1 configuration
  • Point-and-click configuration
  • Complete set of diagnostic tools


SKU: SATRES-6457

Frequency Range
Band 1 Std Ku

    RF

    IF


14.00 to 14.50 GHz

950 to 1450 MHz
Band 2 Full Ku

    RF

    IF


13.75 to 14.50 GHz

950 to 1700 MHz
Band 3 Low Ku

    RF

    IF


12.75 to 13.25 GHz

950 to 1450 MHz
VSWR / Impedance 1.5:1 max / 50 Ohm
Input Connector Type N female (50 Ohm)
Input Connector options Type F (75 Ohm), TNC (50 Ohm)
Input power detector -55 to –20 dBm
Gain
Small Signal Gain (L-band to RF)

with attenuator set to 0 dB

    4W

    8W

    12W

    16W

    20W

    25W

    30W

    40W

    50W




67 dB min

70 dB min

72 dB min

73 dB min

74 dB min

75 dB min

76 dB min

77 dB min

78 dB min
Attenuator range 16 dB variable in 0.1 dB steps
Gain flatness Band 1 and 3

    Full band

    36 MHz

    1 MHz


3 dB p-p max

1 dB p-p max

0.25 dB p-p
Gain flatness Band 2

    Full band

    36 MHz

    1 MHz


4 dB p-p max

1.5 dB p-p max

0.25 dB p-p
Gain variation over temperature

    Open loop

    With AGC


4 dB p-p max

1 dB p-p max
RF Output
Interface WR75 cover with groove
VSWR / Impedance 1.5:1 max
Rated output power (P1dB)

    4W

    8W

    12W

    16W

    20W

    25W

    30W

    40W

    50W


+36 dBm min

+39 dBm min

+40.8 dBm min

+42 dBm min

+43 dBm min

+44 dBm min

+44.8 dBm min

+46 dBm min

+47 dBm min
IMD3 (2 carriers, 3 dB TOBO) -25 dBc max
Level stability with ALC ±0.5 dB
Output power detector range Rated power to –20 dB
Power reading accuracy ±1.0 dB max.
Spurious

    In Band

    Out of Band


-65 dBc

Complies with EN 301 428/430 and MIL-STD 188-164B
Harmonics -50 dBc max.
Output Noise Power Density

    Tx

    Rx


< -80 dBm/Hz

< -145 dBm/Hz
SSB Phase Noise (External reference)

    10 Hz

    100 Hz

    1 kHz

    10 kHz

    100 kHz

    1 MHz


-115 dBc/Hz

-140 dBc/Hz

-150 dBc/Hz

-155 dBc/Hz

n/a

n/a
SSB Phase Noise (IBUC)

    10 Hz

    100 Hz

    1 kHz

    10 kHz

    100 kHz

    1 MHz


-50 dBc/Hz

-75 dBc/Hz

-85 dBc/Hz

-90 dBc/Hz

-95 dBc/Hz

-110 dBc/Hz
External Reference (multiplexed on TX IFL)

    Frequency

    Level


10 MHz

-12 to +5 dBm
Internal Reference - optional
Local Oscillator Frequency
Band 1 13050 MHz
Band 2 12800 MHz
Band 3 11800 MHz
Sense Non-Inverting
IBUC Power Supply
Voltage (DC/AC) 48 ±11 VDC / 100 to 240 VAC
Option for 4W, 8W 24 ±4 VDC
DC via coax available on 4W - 16W
Power Consumption

    4W

    8W

    12W

    16W

    20W

    25W

    30W

    40W

    50W


77 W / 85 VA

110 W / 132 VA

144 W / 158 VA

168 W / 200 VA

220 W / 250 VA

270 W / 297 VA

380 W / 440 VA

400 W / 456 VA

550 W / 600 VA
Monitor and Control
Ethernet (HTTP, Telnet, SNMP) via RJ-45 connector.
RS232/485, Hand-held Terminal via MS-type connector FSK, multiplexed on TX IFL.
Environmental
Operating temperature

    4W - 25W

    30W - 50W


-40 °C to +60 °C

-40 °C to +55 °C
Relative humidity 100% condensing
Altitude 10,000 ft., (3,000 m) ASL
Mechanical

    4W - 8W



    12W - 25W



    30W - 50W

 
(DC powered / AC powered)

12.2 x 7.2 x 4.2 in. / 12.2 x 7.2 x 4.5 in.

13 lbs / 14 lbs

12.2 x 7.2 x 6.2 in. / 12.2 x 7.2 x 6.5 in.

18 lbs / 19 lbs

12.2 x 7.2 x 6.7 in. / 12.2 x 7.2 x 7.0 in.

18.5 lbs / 19.5 lbs

Ratings & Reviews

No reviews available

Be the first to Write a Review