• Home
  • iDirect Evolution X3 Satellite Router




iDirect Evolution X3 Satellite Router

(0) No Reviews yet
  • Next Generation DVB-S2 Router
  • ACM Outbound
  • Built-in TCP and HTTP acceleration
  • Advanced QoS and traffic prioritization


SKU: SATRES-7155

Network Configuration

Network TopologyStar (DVB-S2/ACM Outbound

+ Multi Frequency D-TDMA or SCPC Return*)
Downstream DVB-S2Upstream TDMAUpstream SCPC Return
ModulationQPSK, 8PSK, 16APSK BPSK, QPSK, 8PSKBPSK, QPSK, 8PSK
FECLDPC, 1/4 - 8/9TPC, 0.431 - 0.793**;

2D 16-State, 1/2 - 6/7
2D 16-State, 1/3 - 6/7
Max. Symbol Rate45 Msps7.5 Msps 15 Msps
Max. Info Rate150 Mbps12.8 Mbps 24 Mbps
Max. Line Card IP Data Rate149 Mbps11.1 Mbps 18.2 Mbps
Max. Remote IP Data Rate29 Mbps7.8 Mbps 11.8 Mbps
Max. Remote IP Data Rate29 Mbps7.8 Mbps 11.8 Mbps

Interfaces

Satcom Interfaces
TxIFType-F, 950–1700MHz,

Composite Power +7dBm / -35dBm
RxIF Type-F, 950–2150MHz,

Composite Power -5dBm / -65dBm
Available BUC Power (IFL)+24V, max. 70W, (120W PSU)

(please refer to X3 Installation Manual

for full list of supported BUCs)
Available LNB Power (IFL)+19.0V (Nominal) / +14V (Nominal),

300mA (DiSEqC) 22KHz DiSEqC tone
10 MHz ReferenceSoftware controllable on Tx and Rx IF ports
Data Interfaces

    LAN

    RS-232


10/100 Ethernet, 802.1q VLAN

RJ45 (Console connection)
Protocols SupportedTCP, UDP, ACL, ICMP, IGMP, RIP Ver2,

Static Routes, NAT, DHCP, DHCP Helper,

Local DNS Caching, cRTP and GRE
Traffic EngineeringGroup QoS, QoS

(Priority Queuing and CBWFQ),

Strict Priority Queuing,

Application Based QoS,

Minimum CIR, CIR

(Static and Dynamic),

Rate Limiting
Other FeaturesBuilt-in Automatic Uplink Power,

Frequency and Timing Control,

Authentication, AES-256 encryption

Mechanical / Environmental

Size (W x D x H)11.5 in (29.2 cm) x 9.9 in (25.1 cm) x 2 in (5.1cm)
Operating Temperature0° to +45°C (32° to +113°F) at Sea Level

with temperature gradient of 5°C per 10mins
Humidity Max90% non-condensing humidity
Input Voltage100–240 VAC Single Phase, 50–60 Hz,

2A max at 90 VAC, 1A max at 240 VAC
Radio Standards

    EN 301-428 v1.3.1

    EN 301-443 v1.3.1


Ku-Band System Level Specification

C-Band System Level Specification
Safety StandardsComplies with IEC 60950,

EN 60950-1, UL 60950-1, CSA C22.2 No.60950-1-03
Emission StandardComplies with EN 55022 Class B,

FCC Part 15 Class B, CISPR 22 Class B,

EN 61000-3-2, EN 61000-3-3
EMC/Immunity StandardComplies with EN 55024, EN 301-489-1,

EN 301-489-12, EN 61000-4-2, EN 61000-4-3,

EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN

61000-4-11
CertificationFCC, CE, and RoHS Compliant

Ratings & Reviews

No reviews available

Be the first to Write a Review