• Home
  • Agilis ALB 129 16W Standard Ku-Band BUC




Agilis ALB 129 16W Standard Ku-Band BUC

(0) No Reviews yet
  • Tx Frequency: 14.0 - 14.5 GHz
  • Input Connector: N-Type Female (50 ohm)
  • Output Interface: WR-75G
  • L.O. Frequency: 13.05 GHz


SKU: SATRES-32211

RF Specifications
Transmit Frequency 14.0 - 14.5 GHz
IF Frequency Range 950 - 1450 MHz
Output Power (P1dB) 42 dBm (16W) 44 dBm (25W)
Small Signal Gain 68 dB Min
Gain Flatness ±2 dB over the O/P frequency band
Gain Variation ±2 dB over the operating temperature range
Gain Control 20 dB in steps of 0.5 dB
Inter Modulation -25dBc @ Relative to combine power of two carriers at 3dB total power backoff from Rated Output power
O/P Spurious According to EN301428
Phase Noise @ offset

    1 kHz

    10 kHz

    100 kHz


-73 dBc/Hz

-83 dBc/Hz

-93 dBc/Hz
I/P VSWR 2.0:1
O/P VSWR 1.25:1 (with optional external isolator)
Noise Power Density

    Tx BD

    Rx BD


70 dBW / 4 kHz

142 dBW / 4 kHz
DC Power
Prime Power 48 VDC (range 38 to 60 VDC) via external MS connector
Power Consumption 177.36W (max for 16W/20W)
Interfaces
IF Input Interface 50 ohms N-type Female or 75 ohms F-type Female
Output Interface WR-75G grooved
External Reference
Frequency 10 MHz
Power -5 to +5 dBm
External reference phase noise requirement

@ frequency offset

    1 kHz

    10 kHz

    100 kHz




-135 dBc/Hz

-145 dBc/Hz

-155 dBc/Hz
Monitor & Control
Monitor BUC Temperature

Status Alarm

RF Output Power

LED Status Indication
Control Attenuation

RF output mute
M&C Interface RS232 / RS485 & Ethernet (SNMP & HTTP)

via external MS connector
Tx Redundancy External RCU (optional for 1+1 redundancy system requirement)
Environmental
Operating Temperature -40°C to +60°C

optional (-40°C to +70°C for 16W)
Relative Humidity up to 100%

Weather protection sealed to IP65
Mechanical
Size 200L x 130W x 112.5H mm (16W and 20W)

200L x 130W x 192.5H mm (AC option for 16W & 20W)
Weight 3.5 kg / 7.5 lbs

4.7 kg / 10.36 lbs (AC option)
Color White Powder Coat
Compliance Standard
IEC 609501-2nd Edition International Safety Standard for Information Technology Equipment
ETSI EN 300 489.12 Electromagnetic Compatibility and Radio Spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) Standard for radio equipment and services; Part 12: Specific conditions for Very Small Aperture Terminal, Satellite Interactive Earth Stations operated in the frequency ranges between 4GHz and 30GHz in the Fixed Satellite Service (FSS)
ETSI EN 301 489-1 Electromagnetic Compatibility and Radio Spectrum Matters (ERM); ElectroMagnetic Compatibility Standard for Radio Equipment and Services
FCC Class A Two levels of radiation and conducted emissions Limits for unintentional radiators (FCC Mark)

Ratings & Reviews

No reviews available

Be the first to Write a Review