FREQUENCY RANGE
Output 14.0 to 14.5 GHz
Input 950 to 1450 MHz
LO Frequency 13050 MHz
Input Level, w/o damage (maximum) 10 dBm
Reference Signal Frequency external 10 MHz
10 MHz Power Level 2 dBm ± 5 dB
Reference Input Impedance 50 Ohms
Output Power
Traveling Wave Tube 200 Watts
Rated Power @ Amplifier Flange (minimum) 175 Watts
GAIN
Large Signal (minimum)67 dB
Small Signal (minimum) 72 dB
Attenuator Range (continuous)25 dB
Maximum SSG Variation Over

    Any Narrow Band

  &nbps; Full Band


1.3 dB per 80 MHz

± 2 dB
Slope (maximum) ± 0.04 dB/MHz
Stability, 24 hr. (maximum) ± 0.25 dB
Stability, Temperature (maximum) ± 1.0 dB over temperature range at any frequency
INTERMODULATION (maximum) with two equal carriers -18 dBc @ 4 dB total output power backoff from rated power
HARMONIC OUTPUT (maximum) -60 dBc
AM/PM CONVERSION (maximum) 2.5 deg/dB at 6 dB below rated output power
NOISE POWER (maximum)

    Transmit Band

    Receive Band

 


-70 dBW/4 kHz

-150 dBW/4 kHz

10.95 to 12.75 GHz
Group Delay (maximum)

    Bandwidth

    Linear

    Parabolic

    Ripple


Any 40 MHz

± 0.01 nS/MHz

± 0.005 nS/MHz²

0.5 nS/Pk-Pk
RESIDUAL AM NOISE (maximum) In band discrete spurious -60 dBc > 100 kHz from carrier

AC fundamental -50 dBc

Sum of all spurs -45 dBc
PHASE NOISE (maximum) 10 dB below IESS phase noise profile

AC fundamental -50 dBc

Sum of all Spurs -47 dBc
VSWR

    Input (maximum)

    Output (maximum)


1.6:1

2.2:1

Note: 1.3:1 output VSWR available with optional external isolator
Prime Power
90 to 264 VAC
47 to 63 Hz, Single Phase
850 VA (maximum)
0.96 Minimum Prime Power Factor
Environment
NONOPERATING TEMPERATURE RANGE -50°C to +70°C
OPERATING TEMPERATURE RANGE -40°C to +50°C (2°C/1000 Feet Derating)
HUMIDITY Up to 100% Condensing
ALTITUDE 10,000 Feet MSL Max.
SHOCK AND VIBRATION Normal Transportation
COOLING Forced Air

Ratings & Reviews

No reviews available