• Home
  • Xicom XTRS-50C 50W C-Band SSPA (Rack Mount)




Xicom XTRS-50C 50W C-Band SSPA (Rack Mount)

(0) No Reviews yet
  • 50 Watts C-Band (5.85 to 6.425 GHz)
  • Built-in Redundancy Control
  • Complete Digital M&C Interface
  • Removable Power Supply


SKU: SATRES-23148

XTRS-50C
FREQUENCY RANGE standard Output 5.85 - 6.425 GHz
OUTPUT POWER
Saturated Power (Typical) 47 dBm
Rated Power(P1dB) @ Amplifier Flange 46 dBm
Gain
Small Signal, minimum 65 dB, gain control set for maximum gain
Small Signal, Maximum75 dB, gain control set for maximum gain
Gain Flatness, maximum2.5 dB
Maximum SSG Variation Over 40 MHz 0.8 dB per 40 MHz
Slope, maximum ± 0.04 dB/MHz
Stability, 24 Hr maximum ± 0.25 dB
Stability, Temperature ± 2 dB maximum over temperature range at any frequency
GAIN CONTROL20 dB
Intermodulation

with two signals
- 25 dBc maximum with two equal carriers

at 3 dB total power backoff from rate output
HARMONIC OUTPUT, maximum - 60 dBc
AM/PM CONVERSION, maximum 2.5 deg/dB at 3 dB below rated output power
NOISE POWER, maximum

    Transmit Band

    Receive

 


- 80 dBW/4 kHz

- 150 dBW/4 kHz

3.7 to 4.2 GHz
Group Delay Max over any 40 MHz Bandwidth

    Linear

    Parabolic

    Ripple


± 0.03 nS/MHz

± 0.003 nS/MHz²

1 nS/Pk-Pk
RESIDUAL AM - 50 dBc to 10 kHz

- 20 (1.5 + logf) dBc 10 to 500 kHz

- 85 dBc above 500 kHz
PHASE NOISE, maximum 10 dB below IESS Phase Noise Profile
VSWR

    Input, maximum

    Output, maximum


1.2:1

1.3:1
Prime Power
Working Range 90 MIN. - 264 MAX, VAC
47 to 63 Hz, single phase
400 VA Typical
0.95 Minimum Prime Power Factor
Environmental
NONOPERATING TEMPERATURE RANGE -50° C to + 70° C
OPERATING TEMPERATURE RANGE 0° C to +50° C

2° C/1000 feet derating
HUMIDITY Up to 95% Condensing
ALTITUDE 12,000 feet MSL maximum
SHOCK AND VIBRATION Normal Transportation
COOLING Forced Air (175 CFM Typical)

Ratings & Reviews

No reviews available

Be the first to Write a Review