• Home
  • Xicom XTD-750DBS-B1 750W DBS-Band Antenna Mount Amplifier with Block Upconverter




Xicom XTD-750DBS-B1 750W DBS-Band Antenna Mount Amplifier with Block Upconverter

(0) No Reviews yet
  • Peak Power or CW
  • Short Waveguide run
  • Power Factor Correction
  • High efficiency Dual-Stage TWTs


SKU: SATRES-28279

FREQUENCY RANGE
Output 17.3 to 18.1 GHz

(optional 17.3 to 18.4 GHz)
Input 950 to 1650 MHz
LO Frequency 16350 MHz
Input Level, w/o damage (maximum) 10 dBm
Reference Signal Frequency external 10 MHz
10 MHz Power Level 2 dBm ± 5 dB
Reference Input Impedance 50 Ohms
Output Power
Traveling Wave Tube 750 Watts CW
Rated Power @ Amplifier Flange (minimum) 650 Watts
GAIN
Large Signal (minimum)65 dB
Small Signal (minimum) 70 dB
Attenuator Range (continuous)25 dB
Maximum SSG Variation Over

    Any Narrow Band

  &nbps; Full Band


1.0 dB per 80 MHz

3.0 dB
Slope (maximum) ± 0.04 dB/MHz
Stability, 24 hr. (maximum) ± 0.25 dB
Stability, Temperature (maximum) ± 1.0 dB over temperature range at any frequency
INTERMODULATION (maximum) with two equal carriers -18 dBc @ 4 dB total output power backoff from rated power
HARMONIC OUTPUT (maximum) -60 dBc
AM/PM CONVERSION (maximum) 3.0 deg/dB at 6 dB below rated output power
NOISE POWER (maximum)

    Transmit Band

    Receive Band

 


-70 dBW/4 kHz

-150 dBW/4 kHz

10.95 to 12.75 GHz
Group Delay (maximum)

    Bandwidth

    Linear

    Parabolic

    Ripple


Any 80 MHz

± 0.01 nS/MHz

± 0.005 nS/MHz²

0.5 nS/Pk-Pk
RESIDUAL AM NOISE (maximum) In band discrete spurious -50 dBc to 10 kHz

-20 (1.5 + logf) dBc 10 to 500 kHz

-85 dBc above 500 kHz
PHASE NOISE (maximum) -10 dB below IESS phase noise profile

AC fundamental -50 dBc

Sum of all spurs -47 dBc
VSWR

    Input (maximum)

    Output (maximum)


1.3:1

1.3:1
Prime Power
180 to 260 VAC
47 to 63 Hz, Single Phase
2300 VA Typical (XTD-750DBS)
0.95 Minimum Prime Power Factor
Environment
NONOPERATING TEMPERATURE RANGE -50°C to +70°C
OPERATING TEMPERATURE RANGE -40°C to +60°C (2°C/1000 Feet Derating)
HUMIDITY Up to 100% Condensing
ALTITUDE 10,000 Feet MSL Max.
SHOCK AND VIBRATION Normal Transportation
COOLING Forced Air

Ratings & Reviews

No reviews available

Be the first to Write a Review