• Home
  • Xicom Technology XTS-50X1-B1 50W X-Band Solid State Block Upconverter




Xicom Technology XTS-50X1-B1 50W X-Band Solid State Block Upconverter

(0) No Reviews yet
  • High Efficiency
  • Complete Digital M&C Interface
  • RS-232, RS-422, RS-485
  • Optional Ethernet Interface


SKU: SATRES-31581

1.3:1
FREQUENCY RANGE
Output 7.9 to 8.4 GHz
Input 950 to 1450 MHz
LO Frequency 6950 MHz
Input Level, w/o damage (maximum) 10 dBm
Reference Signal Frequency external 10 MHz
10 MHz Power Level 2 dBm ± 5 dB
Reference Input Impedance 50 Ohms
Output Power
Rated Power @ Amplifier Flange (P1 dB typ) 47 dBm
Linear Power (minimum) 45 dBm
GAIN
Small Signal (minimum) 50 dB
Maximum SSG Variation Over

    Any Narrow Band

    Full Band


± 0.5 dB per 40 MHz

± 1.50 dB
Slope (maximum) ± 0.04 dB/MHz
Stability, 24 hr. (maximum) ± 0.25 dB
Stability, Temperature (maximum) ± 2.0 dB over temperature range at any frequency
INTERMODULATION (maximum)

with two equal carriers @ Linear Power
-25 dBc
SPECTRAL REGROWTH @ Linear Power -30 dBc, 1 SR, OQPSK
HARMONIC OUTPUT (maximum) -60 dBc
AM/PM CONVERSION (maximum) 2.0 deg/dB at Linear Power
NOISE POWER (maximum)

    Transmit Band

    Receive Band


-75 dBW/4 kHz

-75 dBW/4 kHz
GROUP DELAY (maximum)

    Bandwidth

    Linear

    Parabolic

    Ripple


Any 40 MHz

± 0.01 nS/MHz

± 0.005 nS/MHz²

0.5 nS/Pk-Pk
RESIDUAL AM NOISE (maximum)

In band discrete spurious
-60 dBc > 100 kHz from carrier

AC fundamental -50 dBc

Sum of all spurs -47 dBc
OUTPUT SPURIOUS @ RATED POWER (P1dB) -60 dBc
Phase Noise

    100 Hz

    1 kHz

    10 kHz

    100 kHz

    1 MHz



-63 dBc/Hz

-73 dBc/Hz

-83 dBc/Hz

-93 dBc/Hz

-103 dBc/Hz
10 MHz REFERENCE PHASE NOISE (maximum)

    1 kHz

    10 kHz

    100 kHz


-150 dBc/Hz

-160 dBc/Hz

-160 dBc/Hz
VSWR

    Input (maximum)

    Output (maximum)


1.8:1

Prime Power
20 to 32 VDC 330 VA Typical
ENVIRONMENT
NONOPERATING TEMPERATURE RANGE -50°C to +70°C
OPERATING TEMPERATURE RANGE -40°C to +60°C

(2°C/1000 Feet Derating)
HUMIDITY Up to 100% Condensing
ALTITUDE 12,000 Feet MSL Max.
SHOCK AND VIBRATION Normal Transportation
COOLING Forced Air
Interface
REMOTE CONTROL Transmit ON/OFF Fault Reset

RF Inhibit
REMOTE STATUS
Transmit ON/OFF Summary Fault
Temperature (°C) RF Inhibit (ON/OFF)
Forward Power (Optional) Fault Identification

Lock Detect

Over Temperature
XICOM COMMAND SET ASCII Commands

Ratings & Reviews

No reviews available

Be the first to Write a Review