|
|
|
|
Squire Tech Solutions pCom™ 300 Power Communications Trailer
The Squire Tech Solutions pCom™ is a mobile infrastructure trailer designed to supply essential clean power, communications, lighting, and storage for diverse locations, needs and applications.
|
|
|
|
|
|  |
|
|
pCom 300 Power Communications Trailer System
Squire Tech Solutions’ pCom™ 300 is a mission critical power
communications trailer system for government and private
industry mobile infrastructure needs.
The pCom™ 300 provides an immediately deployable, self contained power
generator, lighting and satellite communications infrastructure where you need it.
Emergency management and field operations require an infrastructure
designed to solve the problems that come with the unknown. The flexible
design of the pCom 300 offers an environment to operate vital equipment
and services to IT and Incident Operations Management personnel.
pCom 300 Applications
- Incident Response
-
Communications and
Power Restoral
-
On-Demand Services
-
Remote Field Operations
All electronics bays have NEMA4 extreme environment enclosure with
controls for humidity, water intrusion, heat, cooling, and air-born particulate
filtration. The pCom’s on-board 10,000 watt ultra quiet power generation
system provides for site power, core communications equipment and
powerful scene lighting system. The clean power generation, a 105 gallon
internal diesel tank, and an auto-acquire satellite antenna, when combined
with a standard 30’ internally cabled tower, creates the ultimate response
trailer. With 40 rack units of environmentally controlled rack space, pCom
operators have numerous options for their critical communications
equipment. Whether you run proprietary internal networks or you simply
require reliable access to high-speed internet, phones, radio, video, or
broadcast, the pCom 300 fulfills your needs.
CLICK HERE for a Video Tour of the pCom 300.
Squire Tech Solution's pCom 300 includes the Following |
- Secure NEMA4 communications enclosure
- 40 RU equipment rack space on air suspension
- Secure wiring and cabling access
- Instrumentation control: generator controls, runtime
digital hours meter, system monitor, psi pressure gauges,
tower control
-
10kw Perkins diesel power generator with vibration
isolation, sound dampening and attenuation
-
105 gallon fuel tank
-
Multiple external GFI power outlets
-
External "Patch Ports" and secure conduit
-
Shore power inputs with transfer switch and integrated
battery charger
-
30.5' Tempest Fireco pneumatic tower with internal
cable set
-
Integrated air compressor for pneumatic tools and
tower system.
-
Front and rear air compressor hose connections
Tower mounted
- high power scene lighting
-
AvL auto acquire low stow satellite antenna and control
system with BUC/LNB kit
|
- Satellite modem, router, and rack kit
-
Multi-Port enterprise VoIP router and switch
-
Engenius™ long range 600mW wireless access point /
client bridge
-
Engenius high powered cordless phone system and
outdoor antenna
-
Multi-port PoE Smart switch with Layer 2 / Layer 3
management and controls
-
Power management with UPS
-
Large storage bay with dual door access (over 40 cubic ft.)
-
Marine metal-lock anti-rust coating
-
Tie down "D" rings
-
Integrated anti theft locking coupler system
-
All enclosure doors have key locks
-
Tire rack and spare wheel/tire
-
Integrated trailer brakes, lighting, and brake-away
-
Hydraulic braking system
-
Integrated leveling jacks
-
Transportable by standard vehicle
|
pCom 300 Design Features
- Towable by any standard ½ ton truck
- Internal fuel tank 10 day run time
- Secure conduit throughout structure
- Storage area with management console (power, lights, compressor, tower, air conditioning/heating, phone ports)
- Multiple power outlets internal and external.
- Large secure storage compartment
- Integrated heavy duty leveling jacks
|
 |
pCom 300 Communications Applications |
|
- Satellite Phone and Data Coms
- Radio Repeater System
- Radio "IP" Interoperability
- Cellular Air Cards
- Wireless and Microwave Tower
- 911 Dispatch Restoral
- Critical Site Backhaul
|
Power Generation
- Perkins 10KW diesel generator
- 10 days on internal tank
- Sound insulation and noise suppression
- Power bypass with "shore power" inputs
- Kill switch and safety controls
- Trickle charger and DC power management
- Integrated "clean" UPS power bank and controller
|
Electronics Enclosure
- Meets NEMA4X spec (hose directed water, dust, debris and airborne particulates)
- 7500 BTU air conditioning and heating unit
- Vibration / air ride system on all equipment racks
- Pass through ports and storage enclosure coms panels
- Secure key latch system to all access panel doors
|
Integrated Tower
- Standard 30.5’ pneumatic tower
- Single button deployment in under 3 minutes
- Internal tower cable bundle with management enclosure for Lights, Antennas, and Camera Systems
- Safety Switch and Quick Release
- Secure conduit between coms enclosure and tower base
- 5,000 Lumen Pro LED Lights
|
Flexibility
- TWO racks with a total of 40 rack units for customer equipment
- Power able to support large scale amplification systems
- Internal conduit and cable management throughout
- Tower system designed for adding antennas
- Internal secure cabling (inside the tower)
- Roof antenna mounting channel
|
tab 2
|
|
|
|
|
|
|
|
|