• Home
  • Paradise Datacom Ku-Band Compact Outdoor Solid State Power Amplifiers (SSPAs)




Paradise Datacom Ku-Band Compact Outdoor Solid State Power Amplifiers (SSPAs)

(0) No Reviews yet
  • Ku-Band 14.00 to 14.50 GHz
  • Ext. Ku-Band 13.75 to 14.50 GHz
  • Power Output to 125W
  • Noise Figure 10 dB @ max gain


SKU: SATRES-5794

Electrical
Frequency Range14.00 to 14.50 GHz
Output Power @: Saturation/P1dB

(Typical/Guaranteed minimum)

HPAK-2010A-CO

HPAK-2020A-CO

HPAK-2025A-CO

HPAK-2035A-CO

HPAK-2040A-CO

HPAK-2050A-CO

HPAK-2070A-CO

HPAK-2100A-CO

HPAK-2125A-CO
Psat/P1dB



40.0/39.0 (10/8) dBm (W)

43.0/42.0 (20/16) dBm (W)

44.0/43.0 (25/20) dBm (W)

45.5/44.5 (35/28) dBm (W)

46.0/45.0 (40/31) dBm (W)

47.0/46.0 (50/40) dBm (W)

48.5/47.5 (70/56) dBm (W)

50.0/49.0 (100/80) dBm (W)

51.0/50.0 (125/100) dBm (W)
Gain range55-75 dB
Gain Flatness full band±1.0 dB
Gain Slope per 40 MHz±0.3 dB
Gain Variation vs. Temperature

-40°C to +55°C
±1.0 dB
Gain Adjustment 0.1 dB resolution adjustable by either

serial or analog voltage input: 0.5 to 2.5 VDC
20 dB
Intermodulation Distortion 3dB back off relative to P1dB-25 dBc
AM/PM Conversion (@ rated P1dB)3.5 °/dB
Spurious (@ rated P1dB)-70 dBc
Harmonics (@ rated P1dB-3dB)-50 dBc
Input/Output VSWR1.3:1
Noise Figure at maximum gain10 dB
Power Requirements

    Line Voltage (power factor corrected)
90 to 265 VAC
    Line Frequency47 to 63 Hz
    Line Power:

      HPAK-2010A-CO

      HPAK-2020A-CO

      HPAK-2025A-CO

      HPAK-2035A-CO

      HPAK-2040A-CO

      HPAK-2050A-CO

      HPAK-2070A-CO

      HPAK-2100A-CO

      HPAK-2125A-CO


170 W

300 W

350 W

450 W

550 W

680 W

750 W

1350 (180-265 VAC only) W

1650 (180-265 VAC only) W
Monitor & Control
User Interface includes:

Summary alarm (out)

Auxiliary alarm (out)

Summary alarm (out)

Auxiliary alarm (out)

Voltage alarm (out)

Current alarm (out)

Temperature alarm (out)

Remote mute (in)

Auxiliary alarm (in)

RF power monitor (out)

Analog gain adjustment

BUC alarm (option)

M&C Host PC Link


Form C relay

Form C relay

Open collector output

Open collector output

Open collector output

Open collector output

Open collector output

Closure to ground

Closure to ground

+ 4vdc @ Psat

0.5 to 2.5 VDC

Open collector output

RS232 - RS485
Mechanical Specifications
Size width x length x height10.0 x 19.5 x 6.50 inches

254 x 495 x 165 mm
Weight

C-Band to 200W / Ku-Band to 70W

250W C-Band / 100, 125 W Ku-Band


36 lbs. (16.4 kg)

44 lbs. (20 kg)
FinishPaint White; powder coat
Connectors:

RF Input

RF Output

    HPAK-2XXX-CO

    HPAC-2XXX-CO

RF Output Sample

Line Power

Monitor and Control

Link Port

Redundancy Switch


Type N female



WR75 Waveguide Grooved flange

WR137 Waveguide CPR137G flange

Type N female

3-pin MS-type Plug

32-pin MS-type Socket

6-pin MS type Socket

6-pin MS-type Socket
Environmental
Operating Temperature Ambient-40 to +55°C
Relative Humidity Condensing100%
Cooling System Integrated Forced Air