• Home
  • MCL MT4400 TWTA Antenna Mount Traveling Wave Tube Medium Power Amplifier




MCL MT4400 TWTA Antenna Mount Traveling Wave Tube Medium Power Amplifier

(0) No Reviews yet
  • Weather Resistant Antenna Mount TWTA
  • Built-in diagnostics
  • Advanced Thermal Design
  • Rugged for Extreme Environments


SKU: SATRES-6698

Electrical Specifications
Frequency Range(F0):

Standard:

Extended:

Extended:

Extended:


5.850 - 6.425 GHz

Option: 5.850 - 7.100 GHz

Option: 5.850 - 6.750 GHz

Option: 5.725 - 6.525 GHz
Output Power:

Tube Output Flange

HPA Output Flange


750 W (58.75 dBm)

665 W (58.25 dBm)
Gain at Rated Power72 dB
Small Signal Gain77 dB
Attenuation Range30 dB (0.10 Step)
Maximum SSG Variation Over Narrow Band.5 dB/40 MHz
Maximum SSG Variation per 500 MHz2.5 dB
Gain Slope Max± .04dB/MHz
Stability, any Freq. over Entire Temperature± 1.0 dB typical
Stability, Any Freq. ±10°C:°0.75 dB max.
Input VSWR:1.20:1 max. with respect to 50 Ohms
Input VSWR:1.20:1 max. with respect to 50 Ohms
Output VSWR:1.25:1 max.
Load VSWR:2.0:1 max. without damage, continuous
AM/PM Conversion:

At Rated Power:

6 dB Below Rated Power:


6.0°/dB max.

2.5°/dB max.
Residual AM Noise, Max.:

To 10 kHz:

10-500 kHz:

Above 500 kHz:


-50 dBc

-20(1.5+logfkHz)dBc

-85 dBc
Harmonic Output, Max.:-60 dBc
Noise & Spurious, Max.:

Receive Band

(Standard):

(Extended):

Transmit Band (F0):




-150 dBW/4 kHz, 3.4 - 4.2 GHz

-150 dBW/4 kHz, 3.4 - 4.2 GHz

-70 dBW/4 kHz
Phase Noise, Max.:

AC Fundamental:

Sum Of All Except AC Fundamental:
10 dB below IESS Phase Noise Profile

-50 dBc

-47 dBc
Intermodulation

(for 2 equal carriers relative to single carrier rated output):
Total P0IM Product max.
-4 dBc-18 dBc
-7 dBc-24 dBc
Group Delay, Max.:

Linear:

Parabolic:

Ripple:
Any 40 MHz Bandwidth

0.01 ns/MHz

0.005 ns/MHz2

0.5 ns p-p
Prime Power:

Voltage:

Power Consumption:



Power Factor:

In-Rush:

Input Transients:


180 - 264 VAC, 1-phase, 47 - 63 Hz

2.4 KVA typ. at rated power out/1.65 KVA typ. at rated power -10 dB(input power will increase if the HPA is driven to saturation)

0.95 min.

28A max.

EN61000-4-4,4-5,4-11 (Surge, Fast Transients, Line Dropout)