• Home
  • Paradise Datacom 1RU Remote Control Panel for Compact Outdoor series SSPAs




Paradise Datacom 1RU Remote Control Panel for Compact Outdoor series SSPAs

(0) No Reviews yet
  • User friendly Monitor & Control
  • Front panel or remote operation
  • Audible alarms
  • Field programmable firmware


SKU: SATRES-2669

Call for Availability

Call for Availability

General Specifications
Configurations RCP2-1000-CO; Remote Control Panel for Compact Outdoor SSPA
Serial Communications RS-232 / RS-485 2-wire
Parallel I/O Status Outputs Control Inputs Form C Relay Contacts (10 sets) Contact Closure to Ground
AC Input Power 85-265 VAC, 47-63 Hz, 1 A max, >0.93 power factor
Mechanical Dimensions 1.75 in. H x 19 in. W x 13.3 in. D [1 RU]

45 mm H x 483 mm W x 338 mm D
Weight 5 lb. (2.3 kg)
Environmental Temperature 0 - 50o C
Main Serial Port (J4) Pin Outs
PinFunction
1 RS485 TX+ (HPA Transmit +)
2 RS485 TX- (HPA Transmit -)/RS232 TX
3 RS485 RX+ (HPA Receive -)/RS 232 RX
4 RS485 RX- (HPA Receive +)
5 GND
6 Service Request 1 Form C relay NC contact (Closed on HPA Summary Fault)
7 Service Request Common Form C relay common contact
8 Service Request 2 Form C relay NO contact (Opened on HPA Summary Fault)
9 120 Ohm termination (must be connected to pin 4 in order to enable termination)
Local Serial Port (J5) Pin Outs
PinFunction
1 RS485 RX+
2 RS485 RX-
3 RS485 TX-
4 RS485 TX+
5 GND
6,7,8 Not Used
Ethernet Port (J9) Pin Outs
PinFunction
1 TX+
2 TX-
3 RX+
6 RX-
4,5,7,8 GND
48V Power Supply Pin Outs
A,B +48V
C,D -48V
E,f GND
J7, Parallel I/O Connector Pin-out
1 Closed on Power Supply Fault Form C relay NC
2 Open on Power Supply Fault Form C relay NO
20 Power Supply Fault Common
21 1. Standalone mode. Closed on Auxiliary Fault

2. 1:1 Redundancy Mode. Closed on Automatic switchover mode. Form C relay NC
22 1. Standalone Mode. Open on Auxiliary Fault

2. 1:1 Redundancy Mode. Closed on Manual switchover mode. Form C relay NO
3 Auxillary Fault \ Auto-Manual Common
4 Closed on Mute. Form C Relay NC
5 Open on Mute. Form C Relay NO
23 Mute Status Common
24 Closed on BUC Fault. Form C Relay NC
25 Open on BUC Fault. Form C Relay NO
6 BUC Fault Common
7 Closed on High Temperature Fault. Form C Relay NC
8 Open on High Temperature Fault. Form C Relay NO
26 High Temperature Fault Common
27 1. Standalone mode. Closed on Regulator Low Voltage Fault

2. 1:1 Redundancy Mode. Closed on HPA Standby. Form C relay NC
28 1. Standalone Mode. Opened on Regulator Low Voltage Fault.

2. 1:1 Redundancy Mode. Closed on HPA Online Mode. Form C relay NO
9 Regulator Low Voltage Fault\Standby-Online Common
10 Closed on DC Current Low Fault. Form C Relay NC
11 Open on DC Current Low Fault. Form C Relay NO
29 DC Current Low Fault Common
30 Closed on Low Output RF Fault. Form C Relay NC
31 Open on Low Output RF Fault Form C Relay NO
12 Low Output RF Fault Common
17 Mute/Unmute toggle input. 50mS Closure to ground to activate
35 SSPA Online/Standby toggle. 50mS Closure to ground to activate
36 RCP Local/Remote toggle. 50mS Closure to ground to activate
37 Fault clear. 50mS Closure to ground to activate
19 Ground
32 Spare Fault Common
13 Closed on Spare Fault
14 Open on Spare Fault
15 COM Fault Common
33 Closed on COM Fault
34 Open on COM Fault
18, 16 Reserved. Make No Connection

Ratings & Reviews